RAID 10 with six 4 TB drives: three mirror pairs and the odds that matter

By TechCompare · Updated · How we check

Three pairs make a second failure survivable 80% of the time, against 66.7% with four drives. The guarantee is still one drive, so count the odds as a bonus and keep a backup.

Calculator

RAID Calculator

Usable Capacity
12 TB
Total Capacity
24 TB

Storage Efficiency

50%
Fault Tolerance:

Survives 1 drive failure guaranteed, up to 3 if failures hit different mirror pairs

RAID 10 with six 4 TB drives makes three mirrored pairs and stripes data across all three. You get 12 TB of usable space from 24 TB raw, a 50% overhead. Each pair can lose one drive and keep its data. Whether the array survives a second failure depends on where that failure lands, and that's what sets six drives apart from four. For the four-drive version, see RAID 10 with four 2 TB drives.

How this is calculated

The guaranteed number is 1 drive, and that's the worst case. Once one drive dies, only its mirror partner is fatal, since the partner holds the only other copy of that pair's data. The other four drives sit in pairs that are still whole, so losing one of them is survivable.

A second failure is survivable 80% of the time, if each of the five drives left is equally likely to fail. Four of those five sit in intact pairs. Failures stack the same way, up to a point. Three drives can fail, but only if each one hits a different pair. Four failures always double up one pair, so without a rebuild in between, the array is gone.

Drop to four drives and the odds fall. Two pairs leave three drives after the first failure, one of them a partner, so a second failure is survivable only 66.7% of the time.

Rebuilds stay simple. The replacement drive copies its mirror partner, so one 4 TB drive gets read, not the whole array. On a quiet array that's a best case of 7 hours. Real rebuilds run slower when the array is busy, and the degraded pair is the only one with no copy left until the copy finishes.

RAID 6 on the same six drives is the other way to spend them. It gives 16 TB usable, more than this layout's 12 TB, and it survives any two failures wherever they land. RAID 6 guarantees two failures where RAID 10 guarantees one. RAID 6 writes are slower too, because every stripe needs two parity blocks computed and written, while RAID 10 writes go straight to two copies.

You'll find this layout in six-bay servers, VM hosts and database servers, where random writes are heavy and raw capacity comes second.

Verdict

Choose RAID 10 with six 4 TB drives for write-heavy work like databases and VM hosts. You get 12 TB usable from 24 TB raw, a 50% overhead, and a rebuild that copies one drive from its partner. The price is a guarantee of one failure, with 80% odds on the second.

Choose RAID 6 on the same six bays when capacity and a two-failure guarantee matter more than write speed. It gives 16 TB from six bays and survives any two failures.

Either way, RAID isn't a backup. Deleted files, ransomware and a failed controller hit both layouts.

More RAID scenarios

RAID 0 with 2×2 TB
RAID 0 with two 2 TB drives stripes data across both disks, giving you 4 TB of usable capacity and roughly double the sequential read and write speeds of a single drive.
View details
RAID 1 with 2×4 TB
RAID 1 with two 4 TB drives mirrors all data identically across both disks, giving you 4 TB of usable capacity from 8 TB of raw storage.
View details
RAID 5 with 4×4 TB
RAID 5 with four 4 TB drives uses single distributed parity, giving you 12 TB of usable capacity (3 drives' worth) from 16 TB raw.
View details

Frequently asked questions

Can a 6 drive RAID 10 survive 2 drive failures?
Sometimes. It survives two failures when they hit different mirror pairs. For a second failure picked at random among the five drives left, that happens 80% of the time. If the second drive is the partner of the first, the array loses its data.
How many drive failures can RAID 10 with six drives survive?
Up to three, as long as each one lands in a different mirror pair and no rebuild finishes in between. The guaranteed number is one. Four failures always put two drives in the same pair, so the array is gone before a rebuild can help.
Is RAID 10 or RAID 6 better with six drives?
Neither wins every count. RAID 6 gives more usable space, 16 TB against 12 TB, and survives any two failures. RAID 10 has faster writes and a rebuild that copies one drive from its partner. Pick it for write-heavy work and RAID 6 for capacity and guarantees.