RAID 6 with four 8 TB drives: double parity in the smallest array

By TechCompare · Updated · How we check

Four 8 TB drives in RAID 6 give 16 TB usable and survive any two failures. RAID 10 can't promise that on four drives. You pay 50% of the raw space for that protection.

Calculator

RAID Calculator

Usable Capacity
16 TB
Total Capacity
32 TB

Storage Efficiency

50%
Fault Tolerance:

Survives 2 simultaneous drive failures

RAID 6 with four 8 TB drives gives you 16 TB of usable space from 32 TB raw, and it survives any two drive failures. Four drives is the minimum for RAID 6, so this is the smallest double parity array you can build. It fits a four bay box where losing the array to a second failure during a rebuild isn't an option.

How this is calculated

RAID 10 on the same four drives gives the same 16 TB, so capacity doesn't separate the two. The cost of RAID 6 lands on writes instead. Each write updates two parity blocks per stripe where RAID 5 updates one, so writes are slower, and that gap is built into the layout.

Against RAID 10, the difference is the second failure. RAID 10 on four drives guarantees 1 failure. After one drive dies, a second failure only spares the array if it lands in the other mirror pair, which is two of the three drives that remain. That's 66.7% of the time when the second failure picks a remaining drive at random. RAID 6 survives any second failure.

A single failure on this array reads the three survivors, 24 TB. On a quiet array, one 8 TB drive takes about 14 hours at best. The second parity block means a second failure during that window still leaves the data intact.

Four bays is the floor, and each extra drive lowers the parity share. Six drives bring the overhead down to 33%, and eight drives bring it to 25%.

RAID 5 on three of these drives gives the same 16 TB, but it survives one failure where this layout survives two.

Verdict

Pick this for a four bay box where a second failure must not cost the array, and where you accept 50% of the raw space going to parity. Compare it with RAID 5 on three drives first, since that trades away the second failure tolerance for one fewer drive. Either way, RAID isn't a backup.

More RAID scenarios

RAID 0 with 2×2 TB
RAID 0 with two 2 TB drives stripes data across both disks, giving you 4 TB of usable capacity and roughly double the sequential read and write speeds of a single drive.
View details
RAID 1 with 2×4 TB
RAID 1 with two 4 TB drives mirrors all data identically across both disks, giving you 4 TB of usable capacity from 8 TB of raw storage.
View details
RAID 5 with 4×4 TB
RAID 5 with four 4 TB drives uses single distributed parity, giving you 12 TB of usable capacity (3 drives' worth) from 16 TB raw.
View details

Frequently asked questions

Does RAID 6 with four drives survive two drive failures?
Yes. Any two of the four drives can fail at once, and the data stays intact. A third failure before the array is rebuilt loses it, so the length of the rebuild matters.
Is RAID 6 or RAID 10 better with four 8 TB drives?
Both give 16 TB here, so the choice rests on failure behavior and writes. RAID 6 survives any two failures. RAID 10 survives a random second failure 66.7% of the time, and it skips the parity write cost.
How many drives does RAID 6 need?
At least four. The parity takes two drives' worth of space, so a four drive array keeps 2 drives' worth of data.